General interface
- Improved tab interface and enhanced Quick Access Panel functionality
- Improved search includes pipe and junction notes, names and numbers
- Output reports in German and Chinese languages
- Main menus are translated into available output languages
Graph Results
- Multiple Graphs Sets can be added to Graph Folders for easy generation and display
- Multiple graph tabs on primary window Graph tab
- Multiple parameters can be stacked on separate graphs using the same X-axis
- Secondary Y-parameter for most graph types
- Multiple graphs tiled on same Graph tab
- Multiple graphs can be animated at the same time
- New graphs can be defined directly from the Workspace
- New parameters such as Kv, Cv rate of change, valve position, liquid accumulator volume
- Easy formatting of titles, axis labels, and plot lines
- Plot series lines can be turned on/off for quick inspection
- Graph controls now located on the Quick Access Panel for easy graph definition and changes
- Animations can be saved in MP4 and QuickTime formats
- New Graph Guide to quickly direct new and experienced users to basic and advanced graphing features
Scenario Manager
- Scenario manager shows which scenarios have output
- Ability to create child scenarios without results saving duplication and load time
Workspace
- New paste preview mode allows the pipes and junctions to be placed where desired and will indicate interference with existing objects on the Workspace
- GIS shape files can be imported to create a model
- Text alignment options in annotations
- Annotations can be layered on the Workspace
Output
- Results Diagrams which graphically show data for pumps
Visual Report
- Automatic Color Map generation
Pipes
- Design Alerts are specified and named globally and applied to pipes
- New Design Alerts available
Junctions
- New Turbine junction type
- Surge Anticipator valve capability added to the Relief Valve
- Remote pressure sensing capability added to the Relief Valve
- Improved clarity for data entry in the Reservoir/Tank Property window
- Automatic generation of Cv vs. Time using equal percentage or linear profiles
- New events basedon Cv or Kv
- Maximum pressure setting for Gas Accumulators simulates a relief valve
- When the speed is set for a pump, both the original and modified pump curves are shown on the Pump Property window
- Design Alerts can be applied to junctions
- New dynamic check valve model
- New method from Thorley for estimating reverse velocity through check valves at closure
Forces
- New Force Summary report available in the output showing all applied force sets
- New Design Alerts can be applied to Force Sets and shown in the Force Summary
- New Force report in Model Data showing the input details
- Force definitions can be imported from an Excel file
Animations can be saved in MP4 and QuickTime formats
Enhanced check valve modeling based on inertia